The Importance of Howler Systems in Fire Safety
Construction and temporary sites present unique fire risks due to ever-changing layouts, mobile equipment, and dispersed work zones. A reliable alarm network is essential for promptly alerting everyone in case of danger. The Howler range – including GOLink, HO alarms, and site alert units – offers a flexible, customisable approach suitable for varied environments.
Overview of HO Alarms?
HO alarms are battery-operated, standalone units designed for temporary spaces such as site cabins or unconnected site areas. No hard-wired connection is required, making installation straightforward.
- Loud warning: Generally 102 dB at 1 metre.
- Strobe integration: Available units feature a strobe light alongside the audible siren.
- Durable casing: Many are IP-rated for external or semi-exposed installation.
HO alarms augment main systems, covering areas not reached by the primary site alert infrastructure.
The Howler Site Alert Systems
The Howler Site Alert system suits smaller and medium-sized sites. Each unit can work independently or be wired together with up to 20 others. When triggered, all connected units will sound and flash, ensuring comprehensive coverage.
- Audible warning: Approx. 100 dB at 1 m
- Visual cue: Built-in red LED beacon
- Best used where cable runs are feasible
Wireless Variant
Where wiring is impractical, the Site Alert RF allows up to 30 devices to connect wirelessly to a master unit. With up to 1 km open-air range and multiple frequency channels, this setup is ideal for larger or temporary layouts.
Hybrid arrangements using both wired and wireless units are common and offer better coverage.
Using the GOLink System Effectively
GOLink more info acts as a wireless hub, supporting site-wide communication and coordination.
GOLink Interface Unit
This module connects Howler alarms to external systems (e.g. CCTV, access control), allowing signals to cascade when an event occurs. Up to 127 stations can communicate over the GOLink network.
Dual Use Functionality
Some models, such as the H05 GOLink, incorporate separate fire and first aid switches. The latter more info sends a discreet assistance signal to a control point without triggering full evacuation check here unless specified.
Best Practices for Deployment
- Zone planning: Map the site into clear zones (e.g. cabins, workshops) and position units for optimal reach.
- Wired & wireless balance: Use wired alarms where infrastructure allows; RF units in more temporary areas.
- Regular testing: Weekly or monthly inspections to confirm functionality and battery levels.
- Staff training: Ensure all personnel understand alarm tones, first aid indicators, and emergency response steps.
FAQs
- How many alarms can I link together?
- Up to 20 wired Site Alert units using 2-core cable.
- How far does it reach?
- Approx. 1 km in open air (may reduce with obstacles).
- Do HO alarms need a control panel?
- No. HO alarms operate independently without central panels.
- Can GOLink connect to other systems?
- Yes, via the Interface Unit. External systems such as CCTV and turnstiles can be integrated.
- What is an alarmed switch cover?
- It reduces false alarms by requiring cover removal before pressing. An alert sounds if tampered with.
- Can wired and RF units be used together?
- Yes. Mixed networks are common and synchronised through the GOLink system.
- Does first aid alert trigger full system?
- No. The signal is isolated unless configured otherwise.
Final Thoughts
Effective fire safety requires adaptable, clearly communicated alarm strategies. The Howler suite, including HO alarms, Site Alerts and GOLink systems, provides dependable protection for sites of all types. For product specifications, planners, or live demonstrations, visit the Howler section at FireSense.